Marque : The Modal Shop

  • 9155D-C6251

    Calibration service for NI 6251 PCI DAQ card. A2LA or equivalent 17025 accreditation

    Publié le 


  • 9155D-C427

    Calibration service for TMS Model 9155D-427.  Calibration of PCB 482C27 ICP® Sensor Signal Conditioner and 422 series In-line Charge Amplifier. A2LA accredited.

    Publié le 


  • 9155D-C405

    Calibration service for TMS Model 9155D-405.  Calibration of PCB 482C05 ICP® Sensor Signal Conditioner and 422 series In-line Charge Amplifier. A2LA accredited.

    Publié le 


  • 9155D-C301P

    Reference standard calibration service for TMS Model 9155 systems including a 301A10 or 301A11 reference standard. Calibration is performed by a primary method using laser interferometry. Includes Data on disk. A2LA accredited.

    Publié le 


  • 9155D-C301-LF

    Low frequency reference standard calibration service. Calibration of PCB 301 style reference accelerometer system from 0.5 Hz to 10 Hz by optical encoder. Includes Data on disk. A2LA certified. Requires calibration service 9155D-C301.

    Publié le 


  • 9155D-917

    Acoustic Microphone Option for Model 9155 Calibration System. Calibrates from 31.4 Hz to 10kHz with Model 9917C and ICP Reference Microphone. Includes 9155D-910 software option.

    Publié le 


  • 9155D-910

    Software Only Option For Acoustic Microphone Support. IEC 61094-5 Comparison Method With Acoustic Field Correction (Free Field, Random Incidence)

    Publié le 


  • 9155D-780

    Optical Low Frequency Option for Model 9155 Calibration System. Calibrates from 0.1 Hz to 10 Hz with 25 cm long stroke shaker, integral controller with precision optical displacement feedback control. Available for newly quoted systems.

    Publié le 


  • 9155D-650

    4-20ma Velocity Sensor Calibration option for 9155D system. Includes Power supply, resistor, and 9155D-600 option.

    Publié le 


  • 9155D-535

    Automated Shock Test Option for Model 9155 Calibration System. Determines sensor linearity between 20g to 10,000g. Includes pneumatically operated exciter.

    Publié le 


  • 9155D-516

    Input and output resistance measurement option used for piezoresistive sensors. Includes software and hardware.

    Publié le 


  • 9155D-511

    Shunt Test Option for Model 9155 Calibration System. Includes customer defineable shunt calibration resistors and test method instructions. Requries signal conditioner option 9155D-USC. Some restrictions on shunt resistors apply.

    Publié le 


  • 9155D-405

    Desktop configuration ICP SUT Signal Conditioner Option for Model 9155 Calibration System. Includes PCB Model 482C05 single channel unity gain signal conditioning and 422 series in-line charge amplifier.

    Publié le 


  • 9106C31/482

    Spare Reference Shock Accelerometer Set. 301A12, 482 Series Signal Conditioner, and data on disk

    Publié le 


  • 9106C22/482

    Transfer standard reference accelerometer, for use as a double-ended low frequency calibration working standard. Includes 482A21 ICP sensor signal conditioner, sensor cables and secondary calibration data from 0.5 Hz to 3500 Hz, A2LA certified.

    Publié le 


  • 9106C21/482

    Transfer standard reference accelerometer, for use as a double-ended low frequency calibration working standard. Includes 482A21 ICP® sensor signal conditioner, sensor cables and laser primary calibration data from 0.5 Hz to 3500 kHz, A2LA accredit